    Introduction

    Biofilms are microbes attached to a surface. The  microbes form a film on the surface, giving rise to the name biofilm. This Application Note deals specifically  with bacterial biofilms that convert chemicals to  electrical current on electrodes. Because of this   function, we refer to them as electrochemically active biofilms (EABs). Interest in EABs ranges from their function as bioanodes and biocathodes in microbial fuel cells to new types of biosensors as well as novel biosynthesis of sustainable chemicals.

    This application note shows results for Geobacter sulfurreducens, an oxygen-intolerant species of bacteria able to grow on  electrodes.1

    If you are not familiar with quartz-crystal microbalances, see our Application Note “Basics of a quartz crystal microbalance”.

    Experimental Notes

    Culturing of G. sulfurreducens biofilms is not discussed in this Application Note. G. sulfurreducens is a non- pathogenic  BSL-1  biological agent.

    Unlike typical electrochemical experiments, current  must be collected over several days to give time for the biofilm to grow. Choose an appropriate sampling rate, such as one measurement every five minutes. We show only one day of  growth.

    Gamry’s  jacketed  EuroCell?  Electrochemical  Cell  Kit was used as the reactor vessel. An eSorptionProbe (Part No. 971-18) with 10 MHz Au-coated crystals  was  used.  A saturated Ag/AgCl electrode was used as  reference.

    All parts of the reactor vessel were sterilized prior to biofilm growth.2  The assembled reactor vessel  was therefore sterile. Biological growth medium was then added. Oxygen was purged from the vessel using a gas mixture  of  20%  CO2   and  80%  N2.  The  electrode potential was then fixed to 0 VAg/AgCl using Gamry’s Framework? software with the chronoamperometry script. A suspended cell culture of G. sulfurreducens was added and current was  recorded.

    Results

    Basics of biofilm growth

    Figure 1. Photograph of biofilm grown on the 10 MHz Au-coated crystal for the  eSorptionProbe.

    Biofilm can be grown on the Au-coated crystal (Figure 1). The pink hue on the Au surface is the biofilm. The biofilm is only found on Au because the electrode is the electron sink for the electrons generated from the  biofilm metabolizing acetate (a source of organic  carbon). In order to survive and grow, the biofilm must have an electron sink. As a result, surfaces such as the plastic coating that do not accept electrons show no biofilm growth.

    The biofilm acts as a catalyst for the electrochemical conversion of acetate to carbon dioxide. The half-reaction above is an overall description of what happens in an individual cell in the biofilm. It does not account for carbon assimilation as biomass. The exact path through which electrons follow to reach the electrode surface is complex and not discussed in this Application Note.

    For G. sulfurreducens biofilm, the acetate half-reaction is activated at electrode potentials more positive than approximay ?0.4 VAg/AgCl. This  measured  value  is  true for most Au and C surfaces. Figure 2 shows the result of fixing the electrode potential to 0 VAg/AgCl in the presence of G. sulfurreducens cells and acetate. Cells that attach to the electrode form the initial biofilm.To survive, the initial biofilm metabolizes acetate and produces electrons.This produces an electron flow and is the cause of the increase in current in Figure 2.

    Figure 2. Current output over time of a growing G. sulfurreducens biofilm. The electrode potential was fixed at 0 VAg/AgCl.

    As the biofilm grows, current increases. In effect, the current output over time for EABs is a growth curve. Exponential growth can be easily checked by plotting the data in Figure 2 on a semilogarithmic plot (Figure 3). The initial region is the pre-exponential growth phase or lag phase. The linear region is exponential biofilm growth.

    Figure 3. Semilogarithmic plot of current output over time. The linear region reflects exponential biofilm growth.

    Standard practice is to confirm existence of the biofilm   by using scanning electron microscopy. Figure 4 shows a micrograph of the biofilm after fixation (standard procedure). The flat background is the bare Au surface. The biofilm was purposely removed to show the Au surface and biofilm in the same image.  The micrograph   is a visual indication that biofilm produced the current observed. If the biofilm is distinct like the pink hue in Figure 1, a photograph may be   sufficient.

    Figure 4. Scanning electron micrograph of the biofilm on the Au-coated crystal after growth and a standard fixation procedure. After fixation, the biofilm is no longer alive. Single cells and multi-layered cell clusters are visible.

    Biofilm voltammetry

    During biofilm growth, the chronoamperometry script  can be stopped without damaging the biofilm. This is valuable for a simple voltammetric sweep. Usually cyclic voltammetry is the preferred script because of its simplicity. Figure 5 shows two cyclic voltammograms of    a growing biofilm (replicate) at 44 hours and 49 hours of growth. A catalytic wave is observed with several redox peaks superimposed between ?0.33 VAg/AgCl  to  ?0.23 VAg/AgCl. As the scan reached positive potentials, the effect of the redox peaks is minimized. In this potential region, limiting current is observed. The height of the catalytic wave increases with biofilm  growth.

     

    Figure 5. Cyclic voltammograms of a G. sulfurreducens biofilm during growth. Scan rate was 30 mV/s. (Note that the chronoamperometry scan was stopped in order to run the cyclic voltammetry script.)

    QCM frequency shift

    Cell attachment and biofilm growth can be monitored in real-time using Gamry’s electrochemical quartz-crystal microbalance (eQCM). Using the Gamry Resonator? software, both series frequency-shift (dFseries) and current can be recorded simultaneously. Figure 6 shows dFseries and Reduced (secondary y-axis) during   biofilm growth. This was recorded simultaneously with the current shown in Figure 2. The graphs are separated for clarity.

    Figure 6. dFseries and Reduced over time decreasing in response to biofilm growth on the QCM. These data were taken simultaneously with the current data from Figure 2.

    During the time it took the biofilm to reach a current output  of  40  μA  in  Figure  2,  dFseries  reached  ?1250 Hz. Usually, for rigid films, dFseries can be converted to mass using the Sauerbrey Equation. However, the decrease in Reduced from 1500 to 1000 indicates a significant decrease in the rigidity of the biofilm. As a reference, a ?1800 Hz dFseries shift during copper plating onto the QCM results in a minimal decrease in Reduced from 1280 to 1240. The important point is that it is typically incorrect to use the Sauerbrey  Equation to convert dFseries to mass for a biofilm, because of the biofilm’s viscous nature.

    For most rigid film depositions using the eQCM, a plot of dFseries vs charge yields a straight line (for example, copper plating). In the case of G. sulfurreducens biofilm, this is not true.2 The reason is that charge passed does  not determine how much biofilm has grown on the electrode surface. For example, it is possible to have the total charge passed at the electrode increase with time without biofilm growth. Current passed over time is  more relevant for G. sulfurreducens biofilm because current is a proxy for biofilm growth. Figure 7 confirms this expectation and shows a linear correlation between dFseries and current.

    Figure 7. dFseries vs. current (linear fit in   red).

    Conclusions

    This application note introduces electrochemically active biofilms to researchers outside of the field, and shows how the eQCM can be integrated into basic electrochemical techniques. It may also be useful to high school, undergraduate, or new graduate students who want to learn more about the techniques used to study electrochemically active biofilms. QCMs have a variety of uses in addition to monitoring biofilm growth:

    ?Chemical and biological sensors

    ?Electropolymerization

    ?Li+  intercalation

    ?Corrosion studies

    ?Electrodeposition

    Gamry Instruments would like to acknowledge Dr.Jerome T. Babauta and Professor Haluk Beyenal of the Biofilms Research Group at Washington State University for the generation of these data.

    Application Note Rev. 1.0 1/11/2016 ó Copyright 2016 Gamry Instruments, Inc.



    相關文章

    財報|實現訂單量雙位數增長,賽多利斯2024財年營收33.81億歐元

    2025年2月17日,賽多利斯發布2024年財報。2024年,賽多利斯銷售收入達33.81億歐元,去年同期為33.96億歐元,基本持平;2024年度相關凈利潤為2.8億歐元,較去年同期3.39億歐元略......

    20242025梅特勒托利多實驗室綜合樣本

    梅特勒托利多2024-2025實驗室綜合樣本,集中展示了其在實驗室設備領域的技術和產品。該樣本涵蓋了天平、滴定儀、pH計與電導率儀、密度計與折光率儀、熱值分析儀、紫外可見分光光度計、移液器、熱分析儀和......

    2024年奧豪斯新品推薦填表參與抽獎互動

    2024年奧豪斯推出系列新品,為實驗室在通用設備的選擇上提供了卓越且高效的新方案。新品包括PH電極、磁力攪拌器、大稱量天平、MB系列水分儀、3萬轉高速冷凍離心機、搖床等,以下為您逐一介紹。PH電極新品......

    天平新品專欄|如何應對多通道數據傳輸

    我需要把稱量數據傳到到電腦里做后續的分析;我需要把稱量數據傳輸到我們的LIMS系統里;我需要將稱量數據傳輸到我們的MES系統里;手工記錄麻煩且容易出錯,隨著智能自動化的發展,越來越多的用戶對天平有數據......

    天平新品專欄|如何應對批量樣品稱量數據

    不懼繁瑣,輕松數據管理批量樣品稱量數據如何管理?手工抄錄,費時費力,容易出錯;紙質打印,謄抄錄寫,繁瑣至極;梅特勒托利多新一代高級天平新增稱量結果記事本功能,助您簡化批量稱量工作!稱量結果記事本,針對......

    天平新品專欄|如何應對腐蝕性樣品稱量

    無懼嚴苛環境,稱量隨心所欲!在日常稱量工作中,您是否總被下面的問題困擾:天平又銹又臟,難以清潔;2.樣品具有強腐蝕性,天平用了不到一年,天平表面被腐蝕,或者濺落的液體將接口腐蝕。3.稱量液體頻繁,經常......

    天平新品專欄|如何應對復雜環境下稱量

    在稱量中您是否遇到這樣的困擾?通風柜或層流臺中的稱量遲遲不能穩定,難以捕獲穩定值,稱量重復性差?在空間有限或者需要頻繁稱量的時候,1mg常規帶有防風罩的天平無法擺放或操作繁雜?應采用何種措施來優化稱量......

    清華大學科學博物館舉行天美公司歷史科學儀器捐贈儀式

    2024年4月3日,天美公司向清華大學科學博物館捐贈歷史科學儀器的儀式在清華大學蒙民偉人文樓舉行。天美公司歷史科學儀器捐贈儀式現場本次捐贈儀式由清華大學科學博物館收藏部負責人、科學史系助理教授劉年凱主......

    稱量儀器的日常測試

    “應定期[?]依照國際和/或國內可追溯的測量標準對測量設備進行校準或驗證。”——ISO9001:2008,7.6控制監視和測量設備“應當設計適用于評估設備性能的書面計劃,定期校準、檢測或檢查自動、機械......

    天平使用概念詳解——最小樣品重量

    正確的做法是確定各稱量過程的準確度(允差)要求,即,應用和法規要求的目標稱量值的最大允許偏差。如圖2所示,紅色區中的稱量會產生不正確的稱量值,因為該區的儀器測量不確定度大于稱量過程所需的準確度。因此,......